Ferritaas Incident Intelligence
Defect Intelligence Report Bug 0782390 Severity: High (Driver Buffer Leak)

bcm.user Integrated Switch Fabric Driver Memory Buffer Ring Leak

The internal Broadcom switch fabric management daemon bcm.user on FG-100E/100F/200E appliances leaks DMA buffer descriptors under sustained L2 broadcast, multicast, or ARP traffic, consuming system memory until conserve mode locks management.

Technical Root Cause Analysis

On FortiGate appliances equipped with integrated Broadcom switch silicon (e.g. FG-100E, FG-100F, FG-200E), the user-space driver daemon bcm.user programs internal port VLAN memberships and polls hardware MAC address tables.

When networks encounter high broadcast frames (such as Windows NetBIOS, mDNS, or network scanning tools), the driver allocates packet descriptor rings in host system RAM to buffer packets destined for the control plane. In affected builds, a pointer reference leak prevents completed DMA buffers from being returned to the free pool, causing bcm.user to swell beyond 800MB–1.2GB.

Affected Firmware & Blast Radius Matrix

FortiOS Branch Vulnerable Builds Confirmed Clean Build Status & Workaround
FortiOS 7.0 7.0.0 – 7.0.13 7.0.14+ Enable storm-control rate limiting
FortiOS 7.2 7.2.0 – 7.2.4 7.2.5+ Upgrade recommended / prune broadcast
FortiOS 7.4 Not Affected 7.4.x Branch Clean Updated Broadcom SDK v6.5 natively included

Platform Impact: FG-100E, FG-101E, FG-100F, FG-101F, FG-200E, and FG-201E desktop and 1RU branch appliances.

Step 01: Free Verification CLI (Safe Read-Only)

Execute these commands to check bcm.user memory footprint and switch fabric DMA buffer counts:

Diagnostic Commands

# 1. Check bcm.user memory consumption
diagnose sys top-mem | grep bcm.user

# 2. Dump switch driver DMA ring buffer status
diagnose hardware switch bcm-user stat

# 3. Check switch MAC address table cache depth
diagnose switch-controller dump mac-cache

# 4. Inspect kernel socket buffer allocations
fnsysctl cat /proc/slabinfo | grep -E "kmalloc|skbuff"

Remediation & Workaround Steps (Teaser Preview)

Access the complete storm control and driver stabilization guide in the Ferrite interactive platform:

Step 02: Enable Hardware Storm Control on Internal Switch Ports

Apply rate-limits to broadcast and unknown unicast packets in hardware before driver ingestion.

🔒 Interactive CLI Available in Ferrite Runbook #04

Step 03: Prune Unused VLAN Trunks from Switch Fabric

Remove high-broadcast IoT and guest VLANs from spanning tree interfaces terminating on FortiGate.

🔒 Interactive CLI Available in Ferrite Runbook #04

Step 04: Controlled bcm.user Flush Procedure

Re-initialize the switch fabric driver ring without disrupting established hardware sessions.

🔒 Interactive CLI Available in Ferrite Runbook #04
⚡ Ferrite Platform Superpowers

Execute Runbook #04 with Live Browser Automation

Connect your FortiGate via browser console (Web Serial) or local SSH bridge, verify each command in real-time, generate ready-to-run Tera Term scripts, and export sanitized TAC dossiers.

Live Browser Automation Direct terminal connection with live step checkoff.
📟
1-Click Tera Term (.ttl) Generate scripts for air-gapped jumpboxes.
🛡️
Zero-Trust Scrubber Scrub serials and credentials in local browser RAM.
📄
TAC P1 Escalation Dossier Standardized evidence export with SHA-256 seal.

Frequently Asked Questions

What causes Bug 0782390?

DMA buffer rings inside bcm.user fail to release packet descriptors when processing bursts of layer-2 broadcast and multicast traffic.

Which models are vulnerable?

Only appliances with integrated Broadcom switch silicon, specifically FG-100E/F and FG-200E/F series.

What is the permanent resolution?

Upgrade to FortiOS 7.0.14 or 7.2.5 which updates the Broadcom switch SDK driver with corrected ring deallocation.