Ferritaas Incident Intelligence
Defect Intelligence Report Bug 0883109 Severity: Medium (P3)

FortiGate 200F Shared Interface Policy Conflict during Inter-VDOM Routing

Source NAT (SNAT) and active user authentication policies sharing hardware-accelerated NPU inter-VDOM links collide inside the kernel iprope compiler, corrupting port-translation tuples and dropping inter-tenant transit sessions.

Technical Root Cause Analysis

On mid-range enterprise appliances such as the FortiGate 200F, 201F, and 400F, hardware NP6Lite/NP6xLite network processors accelerate inter-VDOM communications using virtual NPU links (npu0_vlink0 and npu0_vlink1).

In FortiOS 7.2.1 through 7.2.5, when multiple tenant VDOMs enforce Source NAT (SNAT) or user captive portal authentication rules on the same shared inter-VDOM transit interface, the Fortinet Configuration Compiler (fcnfg) fails to segregate translation hash tables across virtual domain namespaces.

When outbound traffic returns from the internet or shared services VDOM, the hardware IP rules property table (iprope) resolves identical port translation tuple IDs across different tenant contexts. The kernel detects an illegal state collision and silently discards the packet, generating repeated iprope match error log traces.

[fcnfg 1082] iprope_add_rule: policy 14 (vdom 'tenant-a') shares interface 'npu0_vlink0' with policy 22 (vdom 'root') [fcnfg 1082] ERROR: NAT IP pool tuple collision (0x0a140102:49152) across inter-vdom link boundary [kernel] iprope_in_check: session 0x7fa28100 dropped - conflicting SNAT translation in vdom root [kernel] id=20085 trace_id=89 func=resolve_ip_tuple line=412 msg="Source NAT port collision on shared vdom-link npu0_vlink0"

Affected Firmware & Blast Radius Matrix

FortiOS Branch Vulnerable Builds Confirmed Clean Build Status & Workaround
FortiOS 7.2 7.2.1 – 7.2.5 7.2.6+ Segregate SNAT IP pools per VDOM
FortiOS 7.4 7.4.0 7.4.1+ Namespace isolation enforced in iprope
FortiOS 7.0 Not Affected 7.0.x Branch Clean Legacy iprope compiler used per-VDOM hashing

Platform Impact: Confined to multi-VDOM deployments on FortiGate 200F, 201F, and 400F appliances running NPU-accelerated inter-VDOM links with overlapping SNAT or user authentication rules.

Step 01: Free Verification CLI (Safe Read-Only)

Execute these diagnostic commands to inspect iprope compiler state and identify conflicting inter-VDOM translation sessions:

Diagnostic Commands

# 1. Inspect compiled hardware iprope rule tables on inter-VDOM links
diagnose firewall iprope list

# 2. Check active iprope compilation state and conflict counters
diagnose firewall iprope state

# 3. Check global session collision counters
diagnose sys session stat

# 4. Filter sessions traversing inter-VDOM link interfaces
diagnose sys session filter clear
diagnose sys session filter intf npu0_vlink0
diagnose sys session list

Remediation & Workaround Steps (Teaser Preview)

Follow the complete step-by-step remediation guide in the Ferrite interactive platform:

Step 02: Identify Overlapping Policies Across Inter-VDOM Links

Audit policy rules on both sides of the inter-VDOM transit path to isolate overlapping IP pools and captive portal settings.

🔒 Interactive CLI Available in Ferrite Runbook #12

Step 03: Assign Dedicated Non-Overlapping SNAT IP Pools

Allocate unique source NAT pools or port blocks to each tenant VDOM to eliminate hash tuple collisions in iprope.

🔒 Interactive CLI Available in Ferrite Runbook #12

Step 04: Switch to Software VDOM Links as Temporary Workaround

Transition from NPU vlinks to software vdom-links to bypass the hardware compiler bug without dropping traffic.

🔒 Interactive CLI Available in Ferrite Runbook #12
⚡ Ferrite Platform Superpowers

Execute the Complete Runbook with Live Browser Automation

Connect your FortiGate via browser console (Web Serial) or local SSH bridge, verify each command in real-time, generate ready-to-run Tera Term scripts, and export sanitized TAC dossiers.

Live Browser Automation Direct terminal connection with live step checkoff.
📟
1-Click Tera Term (.ttl) Generate scripts for air-gapped jumpboxes.
🛡️
Zero-Trust Scrubber Scrub serials and credentials in local browser RAM.
📄
TAC P1 Escalation Dossier Standardized evidence export with SHA-256 seal.

Frequently Asked Questions

What causes Bug 0883109 on FortiGate 200F?

The hardware iprope compiler fails to maintain VDOM namespace boundaries when generating translation tuples for shared NPU links, causing return packets to clash with active sessions in other VDOMs.

Does switching to software VDOM links cause high CPU?

For moderate inter-VDOM throughput (< 2 Gbps), software VDOM links introduce negligible CPU overhead while completely avoiding the hardware iprope hash collision.

Which FortiOS release fixes this permanently?

FortiOS 7.2.6, 7.4.1, and all subsequent builds introduce per-VDOM hash domain tags in the iprope compiler, eliminating translation tuple collisions.