What this article covers
Details diagnostic CLI commands and physical checks to troubleshoot redundant Power Supply Unit (PSU) loss, power redundancy degradation and false failure alarms on FortiGate firewalls.
Before using the CLI
On-site workflow
Inspect the physical power path
Verify PSU seating, power-cable connections and rear-panel status LEDs. Record which supply or feed is reporting the fault.
Query PSU hardware status
Capture the PSU state reported by FortiOS.
diagnose hardware deviceinfo psu
Review hardware sensor output
Look for PSU1 Status, PSU2 Status, voltage and related sensor entries.
execute sensor list
Check system event logs
Filter and review system events for power-supply alarms and transitions.
execute log filter category 1
execute log display
Decide whether TAC or RMA is required
When an alarm begins after a firmware upgrade, verify PSU-controller firmware compatibility. Open a TAC case or RMA request when the PSU remains unpowered.